{"id":1865,"date":"2025-04-02T22:29:11","date_gmt":"2025-04-02T19:29:11","guid":{"rendered":"https:\/\/pciservices.co.il\/newsite\/services\/periodic-testing-and-calibration-of-critical-systems\/"},"modified":"2025-05-28T13:59:32","modified_gmt":"2025-05-28T10:59:32","slug":"periodic-testing-and-calibration-of-critical-systems","status":"publish","type":"services","link":"https:\/\/pciservices.co.il\/en\/services\/periodic-testing-and-calibration-of-critical-systems\/","title":{"rendered":"Routine calibration and verification at process critical systems"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Calibration of process measuring devices<\/h2>\n\n\n\n<p>Performing calibration before the requirements of equipment manufacturers: E&amp;H, METTLER TOLEDO and others .<\/p>\n\n\n\n<p>Periodic calibrations at the customer&#8217;s site<\/p>\n\n\n\n<p>&nbsp;Calibration services &#8211; we plan and carry out calibrations for a wide variety of measuring devices:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>pH and ORP meter &#8211; calibration using certified calibration solutions.<\/li>\n\n\n\n<li>Conductivity meters &#8211; comparative testing by a calibrated master device in low conductivity measurements. Certified solutions in high conductivity measurements.<\/li>\n\n\n\n<li>Oxygen meters &#8211; calibration of dissolved oxygen meters.<\/li>\n\n\n\n<li>Turbidity meters &#8211; comparative testing by a calibrated master device.<\/li>\n\n\n\n<li>Chlorine meters &#8211; comparative testing by a calibrated master device.<\/li>\n\n\n\n<li>Continuous TOC meters &#8211; suitability test by certified liquids of the ALTUS company. https:\/\/www.altusscience.com\/<\/li>\n\n\n\n<li>Measuring dew points &#8211; DEW POINT &#8211; comparative test by a calibrated master device.<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p>&nbsp;Among our clients: leading pharmaceutical companies, semiconductor factories and the defense industry.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calibration of process measuring devices Performing calibration before the requirements of equipment manufacturers: E&amp;H, METTLER TOLEDO and others . Periodic calibrations at the customer&#8217;s site &nbsp;Calibration services &#8211; we plan and carry out calibrations for a wide variety of measuring devices: &nbsp;Among our clients: leading pharmaceutical companies, semiconductor factories and the defense industry.<\/p>\n","protected":false},"featured_media":973,"template":"","class_list":["post-1865","services","type-services","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Routine calibration and verification at process critical systems - PCI<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pciservices.co.il\/services\/\u05d1\u05d3\u05d9\u05e7\u05d5\u05ea-\u05d5\u05db\u05d9\u05d5\u05dc\u05d9\u05dd-\u05ea\u05e7\u05d5\u05e4\u05ea\u05d9\u05d9\u05dd-\u05d1\u05de\u05e2\u05e8\u05db\u05d5\u05ea-\u05e7\u05e8\u05d9\u05d8\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Routine calibration and verification at process critical systems - PCI\" \/>\n<meta property=\"og:description\" content=\"Calibration of process measuring devices Performing calibration before the requirements of equipment manufacturers: E&amp;H, METTLER TOLEDO and others . Periodic calibrations at the customer&#8217;s site &nbsp;Calibration services &#8211; we plan and carry out calibrations for a wide variety of measuring devices: &nbsp;Among our clients: leading pharmaceutical companies, semiconductor factories and the defense industry.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pciservices.co.il\/services\/\u05d1\u05d3\u05d9\u05e7\u05d5\u05ea-\u05d5\u05db\u05d9\u05d5\u05dc\u05d9\u05dd-\u05ea\u05e7\u05d5\u05e4\u05ea\u05d9\u05d9\u05dd-\u05d1\u05de\u05e2\u05e8\u05db\u05d5\u05ea-\u05e7\u05e8\u05d9\u05d8\/\" \/>\n<meta property=\"og:site_name\" content=\"PCI\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-28T10:59:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png\" \/>\n\t<meta property=\"og:image:width\" content=\"120\" \/>\n\t<meta property=\"og:image:height\" content=\"120\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/\",\"url\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/\",\"name\":\"Routine calibration and verification at process critical systems - PCI\",\"isPartOf\":{\"@id\":\"https:\/\/pciservices.co.il\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png\",\"datePublished\":\"2025-04-02T19:29:11+00:00\",\"dateModified\":\"2025-05-28T10:59:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage\",\"url\":\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png\",\"contentUrl\":\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png\",\"width\":120,\"height\":120},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pciservices.co.il\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Areas of activity\",\"item\":\"https:\/\/pciservices.co.il\/services\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Routine calibration and verification at process critical systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pciservices.co.il\/#website\",\"url\":\"https:\/\/pciservices.co.il\/\",\"name\":\"PCI\",\"description\":\"PCI Services\",\"publisher\":{\"@id\":\"https:\/\/pciservices.co.il\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pciservices.co.il\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pciservices.co.il\/#organization\",\"name\":\"PCI\",\"url\":\"https:\/\/pciservices.co.il\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/pciservices.co.il\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/PCI_Logo-yellowblack-1.png\",\"contentUrl\":\"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/PCI_Logo-yellowblack-1.png\",\"width\":188,\"height\":78,\"caption\":\"PCI\"},\"image\":{\"@id\":\"https:\/\/pciservices.co.il\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Routine calibration and verification at process critical systems - PCI","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pciservices.co.il\/services\/\u05d1\u05d3\u05d9\u05e7\u05d5\u05ea-\u05d5\u05db\u05d9\u05d5\u05dc\u05d9\u05dd-\u05ea\u05e7\u05d5\u05e4\u05ea\u05d9\u05d9\u05dd-\u05d1\u05de\u05e2\u05e8\u05db\u05d5\u05ea-\u05e7\u05e8\u05d9\u05d8\/","og_locale":"en_US","og_type":"article","og_title":"Routine calibration and verification at process critical systems - PCI","og_description":"Calibration of process measuring devices Performing calibration before the requirements of equipment manufacturers: E&amp;H, METTLER TOLEDO and others . Periodic calibrations at the customer&#8217;s site &nbsp;Calibration services &#8211; we plan and carry out calibrations for a wide variety of measuring devices: &nbsp;Among our clients: leading pharmaceutical companies, semiconductor factories and the defense industry.","og_url":"https:\/\/pciservices.co.il\/services\/\u05d1\u05d3\u05d9\u05e7\u05d5\u05ea-\u05d5\u05db\u05d9\u05d5\u05dc\u05d9\u05dd-\u05ea\u05e7\u05d5\u05e4\u05ea\u05d9\u05d9\u05dd-\u05d1\u05de\u05e2\u05e8\u05db\u05d5\u05ea-\u05e7\u05e8\u05d9\u05d8\/","og_site_name":"PCI","article_modified_time":"2025-05-28T10:59:32+00:00","og_image":[{"width":120,"height":120,"url":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/","url":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/","name":"Routine calibration and verification at process critical systems - PCI","isPartOf":{"@id":"https:\/\/pciservices.co.il\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage"},"image":{"@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage"},"thumbnailUrl":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png","datePublished":"2025-04-02T19:29:11+00:00","dateModified":"2025-05-28T10:59:32+00:00","breadcrumb":{"@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#primaryimage","url":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png","contentUrl":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/Periodic-testing-and-calibration-of-critical-systems.png","width":120,"height":120},{"@type":"BreadcrumbList","@id":"https:\/\/pciservices.co.il\/services\/%d7%91%d7%93%d7%99%d7%a7%d7%95%d7%aa-%d7%95%d7%9b%d7%99%d7%95%d7%9c%d7%99%d7%9d-%d7%aa%d7%a7%d7%95%d7%a4%d7%aa%d7%99%d7%99%d7%9d-%d7%91%d7%9e%d7%a2%d7%a8%d7%9b%d7%95%d7%aa-%d7%a7%d7%a8%d7%99%d7%98\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pciservices.co.il\/"},{"@type":"ListItem","position":2,"name":"Areas of activity","item":"https:\/\/pciservices.co.il\/services\/"},{"@type":"ListItem","position":3,"name":"Routine calibration and verification at process critical systems"}]},{"@type":"WebSite","@id":"https:\/\/pciservices.co.il\/#website","url":"https:\/\/pciservices.co.il\/","name":"PCI","description":"PCI Services","publisher":{"@id":"https:\/\/pciservices.co.il\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pciservices.co.il\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/pciservices.co.il\/#organization","name":"PCI","url":"https:\/\/pciservices.co.il\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/pciservices.co.il\/#\/schema\/logo\/image\/","url":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/PCI_Logo-yellowblack-1.png","contentUrl":"https:\/\/pciservices.co.il\/wp-content\/uploads\/2025\/03\/PCI_Logo-yellowblack-1.png","width":188,"height":78,"caption":"PCI"},"image":{"@id":"https:\/\/pciservices.co.il\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/pciservices.co.il\/en\/wp-json\/wp\/v2\/services\/1865","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pciservices.co.il\/en\/wp-json\/wp\/v2\/services"}],"about":[{"href":"https:\/\/pciservices.co.il\/en\/wp-json\/wp\/v2\/types\/services"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pciservices.co.il\/en\/wp-json\/wp\/v2\/media\/973"}],"wp:attachment":[{"href":"https:\/\/pciservices.co.il\/en\/wp-json\/wp\/v2\/media?parent=1865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}